ThermistorCalibrationEquationHoge3 {thermocouple} | R Documentation |
Resistance–temperature calibration equation Hoge 1
Description
ThermistorCalibrationEquationHoge3
Resistance–temperature
calibration equation Hoge 3
Usage
ThermistorCalibrationEquationHoge3(Rt, A0, A1, A2, A3, A4)
Arguments
Rt |
resistance measurement for temperature T |
A0 |
equation coefficient A0 |
A1 |
equation coefficient A1 |
A2 |
equation coefficient A2 |
A3 |
equation coefficient A3 |
A4 |
equation coefficient A4 |
Value
T |
temperature |
Author(s)
Jose Gama
Source
Chiachung Chen, 2009 Evaluation of resistance–temperature calibration equations for NTC thermistors Measurement 42, Elsevier
References
Chiachung Chen, 2009 Evaluation of resistance–temperature calibration equations for NTC thermistors Measurement 42, Elsevier
[Package thermocouple version 1.0.2 Index]