calcMRTglobe {comf} | R Documentation |
MRT calculation based on standard and mixed convection
Description
calcMRTglobe
calculates the mean radiant temperature considering mixed convection
Usage
calcMRTglobe(tg, ta, vel, x = 0.15)
Arguments
tg |
- a numeric value presenting globe temperature in [degree C] |
ta |
- a numeric value presenting air temperature in [degree C] |
vel |
- a numeric value presenting air velocity in [m/s] |
x |
- a numeric value presenting globe diameter in [m] |
Details
aliases MRT globe
This model has only been validated from x = 0.040m (ping pong ball) to
x = 0.150m (standard globe thermometer) globes
Value
calcMRTglobe
MRT with standard and mixed correction
Author(s)
code implemented into R by Shaomi Rahman and Marcel Schweiker.
References
Teitelbaum et al. (2022) <10.1038/s41598-022-10172-5> Teitelbaum (2022) <https://github.com/eteitelb/MixedConvection>
Examples
#Globe temperature [C]
tg <- 30
#Air temperature [C]
ta <- 24
#Air speed [m/s]
vel <- 0.0
calcMRTglobe(tg, ta, vel)
[Package comf version 0.1.12 Index]