calcATHBstandard {comf} | R Documentation |
PMV based on Adaptive Thermal Heat Balance Framework for the Standard Model
Description
calcATHBstandard
calculates the PMV based on adaptive thermal heat balance framework
based on the newest version (2022)
Usage
calcATHBstandard(trm, ta, tr, vel, rh, met)
Arguments
trm |
- Running mean outdoor temperature in [degree C] |
ta |
- a numeric value presenting air temperature in [degree C] |
tr |
- a numeric value presenting mean radiant temperature in [degree C] |
vel |
- a numeric value presenting air velocity in [m/s] |
rh |
- a numeric value presenting relative humidity [%] |
met |
- a numeric value presenting metabolic rate in [met] |
Details
aliases athb ATHB
Value
calcATHBstandard
PMV value adapted through the ATHB approach with standard model
Author(s)
Code implemented in to R by Shaomi Rahman. Further contribution by Marcel Schweiker.
References
Schweiker & Wagner (2015) <doi:10.1016/j.buildenv.2015.08.018> Schweiker (2022) <doi:10.1111/ina.13018>
See Also
see also calcComfInd
, link{calcATHBpts}
, link{calcATHBset}
,
link{calcATHBpmv2015}
Examples
calcATHBstandard(20, 25, 25, .1, 50, 1.1)