calcATHBstandard {comf}R Documentation

PMV based on Adaptive Thermal Heat Balance Framework for the Standard Model

Description

calcATHBstandard calculates the PMV based on adaptive thermal heat balance framework

based on the newest version (2022)

Usage

calcATHBstandard(trm, ta, tr, vel, rh, met)

Arguments

trm

- Running mean outdoor temperature in [degree C]

ta

- a numeric value presenting air temperature in [degree C]

tr

- a numeric value presenting mean radiant temperature in [degree C]

vel

- a numeric value presenting air velocity in [m/s]

rh

- a numeric value presenting relative humidity [%]

met

- a numeric value presenting metabolic rate in [met]

Details

aliases athb ATHB

Value

calcATHBstandard PMV value adapted through the ATHB approach with standard model

Author(s)

Code implemented in to R by Shaomi Rahman. Further contribution by Marcel Schweiker.

References

Schweiker & Wagner (2015) <doi:10.1016/j.buildenv.2015.08.018> Schweiker (2022) <doi:10.1111/ina.13018>

See Also

see also calcComfInd, link{calcATHBpts}, link{calcATHBset},

link{calcATHBpmv2015}

Examples

calcATHBstandard(20, 25, 25, .1, 50, 1.1)