disattenuate.d {ufs} | R Documentation |
Disattenuate a Cohen's d estimate for unreliability in the continuous variable
Description
Measurement error (i.e. the complement of reliability) results in a downward bias of observed effect sizes. This attenuation can be reversed by disattenuation.
Usage
disattenuate.d(d, reliability)
Arguments
d |
The (attenuated) value of Cohen's d (i.e. the value as observed in the sample, and therefore attenuated (decreased) by measurement error in the continuous variable). |
reliability |
The reliability of the measurements of the continuous variable |
Value
The disattenuated value of Cohen's d
Author(s)
Gjalt-Jorn Peters & Stefan Gruijters
References
Bobko, P., Roth, P. L., & Bobko, C. (2001). Correcting the Effect Size of d for Range Restriction and Unreliability. Organizational Research Methods, 4(1), 46–61. doi:10.1177/109442810141003
Examples
disattenuate.d(.5, .8);