.get_L {tealeaves}R Documentation

L: Latent heat flux density (W / m^2)

Description

L: Latent heat flux density (W / m^2)

Usage

.get_L(T_leaf, pars, unitless)

Arguments

T_leaf

Leaf temperature in Kelvin

pars

Concatenated parameters (leaf_par, enviro_par, and constants)

unitless

Logical. Should function use parameters with units? The function is faster when FALSE, but input must be in correct units or else results will be incorrect without any warning.

Details

L=hvapgtwdwvL = h_\mathrm{vap} g_\mathrm{tw} d_\mathrm{wv}

Symbol R Description Units Default
dwvd_\mathrm{wv} d_wv water vapour gradient mol / m ^ 3 calculated
hvaph_\mathrm{vap} h_vap latent heat of vaporization J / mol calculated
gtwg_\mathrm{tw} g_tw total conductance to H2O (μ\mumol H2O) / (m2^2 s Pa) calculated

Value

Value in W / m^2 of class units

Examples


library(tealeaves)

cs <- make_constants()
ep <- make_enviropar()
lp <- make_leafpar()

T_leaf <- set_units(298.15, K)

tealeaves:::.get_L(T_leaf, c(cs, ep, lp), FALSE)


[Package tealeaves version 1.0.6 Index]