pH {seacarb} | R Documentation |
Potentiometric pH
Description
Calculation of potentiometric pH
Usage
pH(Ex=-67,Etris=-72.4,S=35,T=25)
Arguments
Ex |
e.m.f. of the seawater sample in mV, default is 67 |
Etris |
e.m.f. of the TRIS buffer in mV, default is -72.4 |
S |
Salinity, default is 35 |
T |
Temperature in degrees Celsius, default is 25oC |
Details
Note that the arguments can be given as a unique number or as vectors. If the lengths of the vectors are different, the longer vector is retained and only the first value of the other vectors is used. It can therefore be critical to use vectors of the same length.
Value
pH |
Potentiometric pH (in mol/kg on the total scale) |
Author(s)
Jean-Pierre Gattuso jean-pierre.gattuso@imev-mer.fr
References
Dickson A. G., Sabine C. L. and Christian J. R., 2007 Guide to best practices for ocean CO2 measurements. PICES Special Publication 3, 1-191.
See Also
Examples
##Example from Dickson et al. (2007)
pH(Ex=-67,Etris=-72.4,S=35,T=25)
[Package seacarb version 3.3.3 Index]