dprime.oddity {psyphy} | R Documentation |
d' for 3 Stimulus Oddity Paradigm
Description
Calculate d'
for a 3 stimulus (triangular) paradigm. Two of the
stimuli are the same and the observer must designate the stimulus that
is different.
Usage
dprime.oddity(Pc.tri)
Arguments
Pc.tri |
numeric in (1/3, 1). The proportion of correct responses for an unbiased observer. |
Value
Returns the value of d'
Author(s)
Kenneth Knoblauch
References
Frijters, G. S., Kooistra, A. and Verijken, P. F. G. (1980) Tables of d'
for the triangular method and the 3-AFC signal detection procedure.
Perception & Psychophysics, 27, 176–178.
MacMillan, N. A. and Creeman, C. D. (1991) Detection Theory: A User's Guide Cambridge University Press
Green, D. M. and Swets, J. A. (1966) Signal Detection Theory and Psychophysics Robert E. Krieger Publishing Company
See Also
dprime.mAFC
, dprime.SD
,
dprime.ABX
Examples
dprime.oddity(0.8)