amp_mix_perc {guescini} | R Documentation |
Amplification mix percentage
Description
This data set is for a set of quantitative real-time PCR runs that targets the amplification of a sequence of the MT-ND1 gene, for a seven-point, ten-fold a serial dilution starting at 3.14 x 10^7 copies of DNA molecules. In addition, a range of amplification mix quantities ranging from 60% to 100% are also performed. This results in 5 serial dilutions, one for each amplification mix quantity (0.6, 0.7, 0.8, 0.9 and 1.0). Please read the Methods section of Guescini et al. (2008) for more details.
Each data set comprises a seven-point, ten-fold dilution series, repeated in
12 independent runs targeting an amplicon for the MT-ND1 gene. A slight
amplification inhibition in the quantitative real-time PCR experiments was
obtained by using two systems: decreasing the amplification mix
(amp_mix_perc
) used in the reaction and adding varying amounts of IgG, a
known PCR inhibitor. Please read the Methods section of Guescini et al.
(2008) for more details.
Format
A tibble with 21,000 rows and 12 variables:
plate
Plate identifier.
well
Well identifier. Values are always
NA
(not available). This variable is kept nevertheless to be coherent with other data sets from other similar R data packages.dye
The type of dye used. In this data set the values are always
"SYBR"
, meaning SYBR Green I master mix (Roche).target
Target identifier: the amplicon used,
"MT_ND1"
.sample_type
Sample type (all curves are standards, i.e.
"std"
).run
This variable discriminates amplification curves within the group defined by
amp_mix_perc
andcopies
. Range:1
thru12
.replicate
Replicate identifier: 1 thru 3.
amp_mix_perc
Amplification mix percentage.
copies
Standard copy number.
dilution
Dilution factor. Higher number means greater dilution.
cycle
PCR cycle.
fluor
Raw fluorescence values.
A tibble with 21,000 rows and 11 variables:
plate
Plate identifier.
well
Well identifier. Values are always
NA
(not available). This variable is kept nevertheless to be coherent with other data sets from other similar R data packages.dye
The type of dye used. In this data set the values are always
"SYBR"
, meaning SYBR Green I master mix (Roche).target
Target identifier: the amplicon used,
"MT_ND1"
.sample_type
Sample type (all curves are standards, i.e.
"std"
).replicate
Replicate identifier: 1 thru 3.
amp_mix_perc
Amplification mix percentage.
copies
Standard copy number.
dilution
Dilution factor. Higher number means greater dilution.
cycle
PCR cycle.
fluor
Raw fluorescence values.
Source
Examples
amp_mix_perc
amp_mix_perc