datasets {errors} | R Documentation |
Datasets from the Guide to the Expression of Uncertainty in Measurement (GUM)
Description
Datasets found in Annex H of the GUM (see reference below).
Usage
GUM.H.2
GUM.H.3
Format
GUM.H.2
, from Section 2 of Annex H (Table H.2), provides
simultaneous resistance and reactance measurements. It is a data frame with 5
rows and 3 variables:
- V
Voltage amplitude, in Volts.
- I
Current amplitude, in Amperes.
- phi
Phase-shift angle of the voltage relative to the current, in radians.
GUM.H.3
, from Section 3 of Annex H (Table H.6), provides
thermometer readings and observed corrections to obtain a linear calibration
curve for some reference temperature. It is a data frame with 11 rows and
2 variables:
- tk
Thermometer reading, in Celsius degrees.
- bk
Observed correction, in Celsius degrees.
An object of class data.frame
with 11 rows and 2 columns.
Source
BIPM, IEC, IFCC, ILAC, IUPAC, IUPAP, ISO, and OIML (2008). Evaluation of Measurement Data – Guide to the Expression of Uncertainty in Measurement, 1st edn. JCGM 100:2008. Joint Committee for Guides in Metrology. https://www.bipm.org/en/committees/jc/jcgm/publications