capillaryPCR {chipPCR} | R Documentation |
capillary convective PCR
Description
The capillary convective PCR (ccPCR) is a modified device of the ccPCR system proposed by Chou et al. 2011.
Usage
data(capillaryPCR)
Format
A data frame with 1844 observations on the following 10 variables.
t.121205
Elapsed time during amplification
ED.121205
a numeric vector
t.121128
Elapsed time during amplification
ED.121128
a numeric vector
t.121130.1
Elapsed time during amplification
ED.121130.1
a numeric vector
t.121130.2
Elapsed time during amplification
ED.121130.2
a numeric vector
t.121130.3
Elapsed time during amplification
ED.121130.3
a numeric vector
Details
Modified version of the capillary convective tube isothermal heater heater by Chou et al. 2011. As heating system a conventional block heat was used. On the top of the heating block, we placed for the uptake of the capillaries an aluminum block (8 mm height) in which four holes (3.2 mm diameter and 3.0 mm depth with round shaped bottom) were drilled. The capillaries are regular 100 micro L Roche LightCycler(R). These glass capillaries have a round shaped closed bottom (2.3 mm inner diameter and 3.2 mm outer diameter). An "ESE-Log" detector (QIAGEN Lake Constance) was used for the real time fluorescent measurements, which was mounted in a distance of 5-10 mm next to the capillary. The PCR was performed with SYBR(R) Green fluorescent intercalating dye. Thereof the ESE-Log has in one channel the excitation at 470 nm and the detection at 520 nm. The data was recorded by the FL Digital Software (QIAGEN Lake Constance) and the exported text based raw data.
Source
Ralf Himmelreich, IMM, Mainz, Germany
References
Chou, W., Chen, P., Miao Jr, M., Kuo, L., Yeh, S. and Chen, P. (2011). Rapid DNA amplification in a capillary tube by natural convection with a single isothermal heater. Biotech. 50, 52-57.
Examples
default.par <- par(no.readonly = TRUE)
# First example
data(capillaryPCR)
plot(NA, NA, xlim = c(0,80), ylim = c(0,1300), xlab = "Time [min]",
ylab = "Voltage [micro V]", main = "ccPCR - Raw Data")
for (i in c(1,3,5,7)) {
lines(capillaryPCR[, i], capillaryPCR[, i+1], type = "b", pch = 20)
}
abline(h = 290, v = c(18, 23, 35))
legend(60,800, c("Run 1", "Run 2", "Run 3", "Control"), pch = 20, lwd = 2)
# Second example
par(mfrow = c(2,1))
type <- c("mova", "spline", "savgol")
plot(NA, NA, xlim = c(0,80), ylim = c(0,1100), xlab = "Time [min]",
ylab = "Voltage [micro V]", main = "ccPCR with mova,
spline and savgol")
for (i in 1:3) {
for (j in c(1,3,5,7)) {
tmp <- data.frame(na.omit(capillaryPCR[, j]),
na.omit(capillaryPCR[, j+1]))
tmp.sm <- smoother(tmp[, 1], tmp[, 2], method = list(type[i]))
lines(data.frame(tmp[, 1], tmp.sm), type = "b", pch = 20, cex = 0.5,
col = i)
}
}
abline(h = 200, v = c(17.5, 21.3, 32.9))
legend(0, 1000, c("mova", "spline", "savgol"), pch = 20, lwd = 2,
col = c(1:3))
plot(NA, NA, xlim = c(10,40), ylim = c(50,300), xlab = "Time [min]",
ylab = "Voltage [micro V]", main = "ccPCR with mova,
spline and savgol")
for (i in 1:3) {
for (j in c(1,3,5,7)) {
tmp <- data.frame(na.omit(capillaryPCR[, j]),
na.omit(capillaryPCR[, j+1]))
tmp.sm <- smoother(tmp[, 1], tmp[, 2], method = list(type[i]))
lines(data.frame(tmp[, 1], tmp.sm), type = "b", pch = 20, cex = 0.5,
col = i)
}
}
abline(h = 200, v = c(17.5, 21.3, 32.9))
legend(10, 300, c("mova", "spline", "savgol"), pch = 20, lwd = 2,
col = c(1:3))
par(mfrow = c(1,1))
# Third example
method <- c("lowess","mova","savgol","smooth","spline", "supsmu")
plot(NA, NA, xlim = c(0,100), ylim = c(-50,1100), xlab = "Time [min]",
ylab = "Voltage [micro V]", main = "capillary convective PCR")
for (i in 1:length(method)) {
for (j in c(1,3,5,7)) {
tmp <- data.frame(na.omit(capillaryPCR[, j]),
na.omit(capillaryPCR[, j+1]))
tmp.sm <- smoother(tmp[, 1], tmp[, 2], method = list(method[i]))
lines(data.frame(tmp[, 1], tmp.sm), type = "l", pch = 20, cex = 0.5,
col = i)
}
}
legend(0,1000, method, pch = 20, lwd = 2, col = 1:length(method))
par(fig = c(0.5,1,0.25,0.8), new = TRUE)
plot(NA, NA, xlim = c(10,40), ylim = c(50,300), xlab = "Time [min]",
ylab = "Voltage [micro V]", main = "")
for (i in 1:length(method)) {
for (j in c(1,3,5,7)) {
tmp <- data.frame(na.omit(capillaryPCR[, j]),
na.omit(capillaryPCR[, j+1]))
tmp.sm <- smoother(tmp[, 1], tmp[, 2], method = list(method[i]))
lines(data.frame(tmp[, 1], tmp.sm), type = "l", pch = 20, cex = 0.5,
col = i)
}
}
legend(0,1000, method, pch = 20, lwd = 2, col = 1:length(method))
# Fourth example
# Comparison of Lowess, Moving average and splines to smooth amplification
# curve data of
# a capillary convective PCR.
plot(NA, NA, xlim = c(10,40), ylim = c(50, 300), xlab = "Time [min]",
ylab = "Voltage [micro V]", main = "ccPCR - Moving average")
movaww <- seq(1,17,4)
for (i in 1:length(movaww)) {
for (j in c(1,3,5,7)) {
tmp <- data.frame(na.omit(capillaryPCR[, j]),
na.omit(capillaryPCR[, j+1]))
tmp.out <- smoother(tmp[, 1], tmp[, 2],
method = list(mova = list(movaww = movaww[i])))
lines(data.frame(tmp[, 1], tmp.out), type = "l", pch = 20,
cex = 0.5, col = i)
}
}
text(10,300, "A)", cex = 3)
legend(25,200, paste("movaww : ", movaww), pch = 20, lwd = 2,
col = 1:length(movaww))
plot(NA, NA, xlim = c(10,40), ylim = c(50, 300), xlab = "Time [min]",
ylab = "Voltage [micro V]", main = "ccPCR - Cubic Spline")
df.fact <- seq(0.5,0.9,0.1)
for (i in 1:length(df.fact)) {
for (j in c(1,3,5,7)) {
tmp <- data.frame(na.omit(capillaryPCR[, j]),
na.omit(capillaryPCR[, j+1]))
tmp.out <- smoother(tmp[, 1], tmp[, 2], method = list(smooth =
list(df.fact = df.fact[i])))
lines(data.frame(tmp[, 1], tmp.out), type = "l", pch = 20,
cex = 0.5, col = i)
}
}
text(10,300, "B)", cex = 3)
legend(30,200, paste("df.fact : ", df.fact), pch = 20, lwd = 2,
col = 1:length(df.fact))
plot(NA, NA, xlim = c(10,40), ylim = c(50, 300), xlab = "Time [min]",
ylab = "Voltage [micro V]", main = "ccPCR - Lowess")
f <- seq(0.01,0.2,0.04)
for (i in 1:length(f)) {
for (j in c(1,3,5,7)) {
tmp <- data.frame(na.omit(capillaryPCR[, j]),
na.omit(capillaryPCR[, j+1]))
tmp.out <- smoother(tmp[, 1], tmp[, 2], method = list(lowess = list(f = f[i])))
lines(data.frame(tmp[, 1], tmp.out), type = "l", pch = 20,
cex = 0.5, col = i)
}
}
text(10,300, "C)", cex = 3)
legend(30,200, paste("f : ", f), pch = 20, lwd = 2, col = 1:length(f))
plot(NA, NA, xlim = c(10,40), ylim = c(50, 300), xlab = "Time [min]",
ylab = "Voltage [micro V]",
main = "ccPCR - Friedman's ''super smoother''")
span <- seq(0.01,0.05,0.01)
for (i in 1:length(span)) {
for (j in c(1,3,5,7)) {
tmp <- data.frame(na.omit(capillaryPCR[, j]),
na.omit(capillaryPCR[, j+1]))
tmp.out <- smoother(tmp[, 1], tmp[, 2],
method = list(supsmu = list(span = span[i])))
lines(data.frame(tmp[, 1], tmp.out), type = "l", pch = 20,
cex = 0.5, col = i)
}
}
text(10,300, "D)", cex = 3)
legend(25,200, paste("span : ", f), pch = 20, lwd = 2, col = 1:length(span))
par(default.par)