| s1 {boggy} | R Documentation |
qPCR data set by Boggy et al. (2010)
Description
The qPCR data set named s1 comprises a six-point, ten-fold dilution series, replicated in duplicates targeting an amplicon designed with a random sequence that minimizes secondary structure and off-target primer binding. Please read the Quantitative PCR data section, qPCR assays subsection of Boggy et al. (2010) for more details.
Format
A tibble with 480 rows and 10 variables:
platePlate identifier. For this data set it is always missing (
NA).wellWell identifier.
dyeThe type of dye used. In this data set the values are always
"SYTO 13", meaning 2 mM of the dsDNA dye SYTO-13 (Invitrogen, Carlsbad, CA).targetTarget identifier: the amplicon used, a random sequence dubbed
"S1"by the original authors.sample_typeSample type (all curves are standards, i.e.
"std").replicateReplicate identifier: either 1 or 2.
copiesStandard copy number.
dilutionDilution factor. Higher number means greater dilution.
cyclePCR cycle.
fluorRaw fluorescence values.
Source
doi:10.1371/journal.pone.0012355
Examples
s1