detection_peleg {bioOED}R Documentation

Detection limit of the Peleg model

Description

Calculation of the detection limit for the Peleg model

Usage

detection_peleg(pars, temperature, limit)

Arguments

pars

list defining the model parameters according to the rules defined in the bioinactivation package.

temperature

numerical value that describes the temperature at which the detection limit will be calculated

limit

numerical value describing the maximum number of log-reductions that can be identified in the experiment limit = logDL - logN0, where DL is the detection limit.

Value

Numerical value that indicates the limit of detection for that temperature for the Peleg model

Examples

 
pars <- list(temp_crit = 56.95,
        k_b = 0.58 ,
        n = 1 )
detection_peleg( pars, temperature = 57, limit=7)

[Package bioOED version 0.2.1 Index]