editLink {antaresEditObject}R Documentation

Edit a link between two areas

Description

Edit a link between two areas

Usage

editLink(
  from,
  to,
  hurdles_cost = NULL,
  transmission_capacities = NULL,
  asset_type = NULL,
  display_comments = NULL,
  filter_synthesis = NULL,
  filter_year_by_year = NULL,
  dataLink = NULL,
  opts = antaresRead::simOptions()
)

Arguments

from

The first area from which to create a link

to

The second one

hurdles_cost

Logical, which is used to state whether (linear) transmission fees should be taken into account or not in economy and adequacy simulations

transmission_capacities

Character, one of enabled, ignore or infinite, which is used to state whether the capacities to consider are those indicated in 8760-hour arrays or if zero or infinite values should be used instead (actual values / set to zero / set to infinite)

asset_type

Character, one of ac, dc, gas, virt or other. Used to state whether the link is either an AC component (subject to Kirchhoff’s laws), a DC component, or another type of asset.

display_comments

Logical

filter_synthesis

Output synthesis

filter_year_by_year

Output year-by-year

dataLink

For Antares v7, a matrix with eight column corresponding to : trans. capacity (direct) trans. capacity (indirect), hurdles cost (direct), hurdles cost (indirect), impedances, loop flow, PST min, PST max. If NULL (default), a matrix whose rows are equal to 1, 1, 0, 0, 0, 0, 0, 0 is set. See Details

opts

List of simulation parameters returned by the function antaresRead::setSimulationPath

Details

The eight times-series are:

NB: For Antares v7 the eight columns must conform to above order. For Antares v6, only five columns are expected, and they must follow this other order: NTC direct, NTC indirect, Impedances, Hurdle cost direct, Hurdle cost indirect.

Value

An updated list containing various information about the simulation.

Note

In Antares, areas are sorted in alphabetical order to establish links between. For example, link between "fr" and "be" will appear under "be". So the areas are sorted before creating the link between them, and dataLink is rearranged to match the new order.

Examples

## Not run: 
editLink(
  from = "area1",
  to = "area2",
  transmission_capacities = "infinite"
)

## End(Not run)