pF_curve {OBIC} | R Documentation |
Water retention curve
Description
This function compute water content at given pressure head, using Van Genuchten water retention curve
Usage
pF_curve(head, thetaR, thetaS, alfa, n)
Arguments
head |
(numeric) suction pressure ([L] or cm of water) |
thetaR |
(numeric) residual water content (cm3/cm3) |
thetaS |
(numeric) saturated water content (cm3/cm3) |
alfa |
(numeric) related to the inverse of the air entry suction, alfa > 0 (1/cm) |
n |
(numeric) a measure of the pore-size distribution, n>1, dimensionless |
Value
theta (numeric) water content (cm3/cm3)
The moisture content of a soil given a certain pressure head. A numeric value.
Examples
pF_curve(head = 2.2, thetaR = 0.01, thetaS = 0.35, alfa = 0.3,n = 1.6)
pF_curve(head = 4.2, thetaR = 0.01, thetaS = 0.35, alfa = 0.3,n = 1.6)